ViatronicsVIATRONICS

SVR-3 Pro with software 5.0

Measure surface velocity without entering the water.

SVR-3 Pro is a handheld radar for rivers and open channels. It measures surface velocity from a bridge or bank, calculates discharge from that measurement and site-specific inputs, and maps surface velocity against distance with Scan, all on the device.

No phone or app requiredBuilt-in data loggingMakita 18 V battery power

SVR-3 Pro from the rear: ribbed aluminium body, sealed USB port with a red O-ring and tethered cap, display window and the radar antenna at the front
  • Measure from the bank or a bridge

    Non-contact radar, so nobody has to wade in high water. The built-in angle sensor measures the tilt, and the device corrects each reading for it automatically.

  • Works on its own in the field

    No phone, app or laptop. Settings, results and the session summary are on the colour touch screen, and the battery is a standard Makita 18 V pack.

  • Sessions logged to the SD card

    With Datalog on, each session is saved with time, settings, angles, result and status, plus GPS position when the receiver has a fix. Download the log over USB.

Software 5.0 in three minutes

What SVR-3 Pro measures, how Scan maps surface velocity against distance, and four methods for estimating mean velocity and discharge.

Play the video: Software 5.0 in three minutes (3 min 25 s, YouTube)
3 min 25 s, English narration with captions (CC). The video plays from YouTube (privacy-enhanced mode) once you press play. Device screens in the video come from the Software 5.0.130 simulator; times and values are examples. Simulated illustrations are marked in the video. All Software 5.0 videos on YouTube

Short clips

Tilt it and watch the map fill in

Height h

Distance on the water x = h / tan V. Drag the tilt to take over; hold still and the reading is assigned to its distance bin. Example surface velocities, map window 25–60°.

Radar
Ka-band Doppler, 12° beam
Angle correction
Built-in angle sensor, V and H
Resolution
0.1 km/h (0.028 m/s)
Power
Makita 18 V tool battery

Spot checks, discharge and surface velocity maps from one screen

Pick the mode in SET, press START. Every session ends in a summary with a status, the angle correction factor and the number of readings left out.

How the mode uses readings

Scan: surface velocity mapped against distance

Mount the radar on a tripod with a pan head and tilt it down step by step. From the tilt angle and the radar height, the device works out where the beam meets the water and assigns each accepted reading to the distance bin of its aim point.

  1. Set the height

    SET, Meas. Mode, Scan. Enter the radar height above the water, 0.5–30 m, from a tape or a laser rangefinder. The distances are only as accurate as the height.

    SET page with Scan selected and the radar height row
  2. Tilt and hold

    Hold each angle within 1° for at least half a second: the status shows HOLD and the readings go onto the map. While you move, it shows MOVE and nothing is used.

    Scan waterfall view: distance across, time down
  3. Read the map

    After STOP the Scan map page shows the whole range as one colour band with its nearest, middle and farthest distance, the radar height, the angle H, the number of readings on the map and how many of the 24 distance bins received readings.

    Scan map summary page: band from red at 2.9 m to green at 10.7 m

Where the 12° beam lands

Beam footprint on the water at h = 5 m, to scale. The tick is the aim point x = h / tan V. At steep angles the footprint is short and the map is sharp; at 18° one reading covers about 11–24 m.

Choose the distance window

The map always has 24 distance bins. They are the grid of the map; the beam footprint decides how sharp the map really is, and one reading can cover several bins. A wider window reaches further with coarser bins; a manual window maps a chosen stretch, for example 10–15 m, best with the radar mounted at about 8 m.

Auto windowRange at h = 5 mOne step1° angle error at the far end
25° (default)2.9–10.7 m0.33 m0.5 m
20°2.9–13.7 m0.45 m0.75 m
15°2.9–18.7 m0.66 m1.3 m

Every reading on the map is logged as a comma-separated SCAN line, so the scan can be redrawn on a PC.

Scan can also give a discharge. Describe the river in Scan setup → Section: the water width, the radar's position from the water's edge, the largest depth and the shape. The summary then shows Q, built from the map slice by slice with the area computed from your description, and Cov, the share of the section under measured bins. Scan Section always applies the log-law profile to the parts of the section, whichever Method is set in the Flow/Discharge menu, and Q is an estimate for the cross-section you describe. How the map becomes a discharge →

Automatic tilt compensation, with angle warnings

The radar measures velocity along its beam. The device corrects it to surface velocity with both angles: the angle sensor measures the tilt V, which the device compensates automatically, and you set the horizontal angle H with H+ and H−.

Surface velocity = measured velocity / (cos V × cos H)

V surface velocity v radar sees v × cos V Side view
Tilt V comes from the built-in angle sensor, about ±1° after Zero V and Cal tilt. A Roll reading works as a spirit level for the tripod.
bridge H flow Top view: set H with H+ and H−, 0–45°
Pointing straight up- or downstream gives H = 0. Pointing diagonally across the river (H 30–45°) lets the scan reach out over the water as the device tilts.

How much a 1° angle error costs

Surface velocity error from a 1° error in V, with H = 0, to scale. The device shows ANGLE WARN when the combined angle between beam and flow, θ = arccos(cos V × cos H), exceeds 50° (cos V × cos H below 0.64). Measurement cannot be started when the tilt angle V exceeds 60°.

Limits the device enforces

Combined > 50°
The angle causing it turns red. The session is allowed and the summary shows ANGLE WARN.
V > 60°
START is refused. During a session it ends as INVALID. In Scan the reading is left off the map and the session continues.
V < −3°
The radar points up: START is refused with “Aim down”.
Zero reference not set
CAL? on the main screen until Zero V is stored. Changing the zero reference by more than 3° requires two confirmations.

For the best accuracy keep V at 30–45° and H as small as you can.

Discharge, calculated on site

Discharge (volumetric flow rate) is the volume of water passing the cross-section per second, in m³/s. Enter the cross-sectional area A, choose how the velocity coefficient k is set, set the duration and press START. The device calculates Q from every valid reading, adds up the volume while they arrive and stops by itself.

Discharge Q (m³/s) = surface velocity v × k × A

Volume (m³) = Σ ( Q × time ), the discharge integrated over time

A 0.1–99.9 m² Cross-section across the river surface velocity mean = k × surface k ≈ 0.85 Velocity from surface to bed
The radar measures surface velocity. The velocity coefficient k (surface-to-mean ratio) turns it into an estimate of the mean velocity of the cross-section. Software 5.0 gives four ways to set k: a fixed value (0.50–1.00, default 0.85), a power-law profile, the log law or Chiu's entropy method, and limits k to 0.30–1.00. Fixed k, Profile and Log take the reading as a representative surface velocity, and Profile and Log describe one vertical line; Entropy treats the reading as the maximum velocity umax, and the device shows the resulting ratio as k. At k = 1.00 the result is marked UNCORR. In Scan, a river section set in Scan setup gives the area and a log-law k for every depth (Scan Section). Where k comes from →

Both flow directions, kept apart

Forward and reverse volumes are stored separately. The totaliser decides how they combine into the result. Example values:

TotaliserRuleResult
ABSBoth directions as magnitudes, sign of the prevailing one+325.47 m³
POSForward only312.40 m³
NEGReverse only−13.07 m³
NETForward minus reverse299.33 m³

Forward 312.40 m³ and reverse 13.07 m³ over a 30 s session. The duration starts at the first valid reading, and any gap after it marks the session INCOMPLETE, with the covered and missing time on the Flow details page.

Session summary: Result 325.47 m3, COMPLETE, SD OK, Dur 30 s, c 1.02, k 0.85 ABS

How the software calculates discharge

The radar measures surface velocity. SVR Software 5.0 combines this measurement with site-specific information to estimate the mean velocity of the cross-section, then calculates discharge as Q = v · k · A: the radar reading v, the velocity coefficient k and the cross-section area A. In Discharge mode it also integrates Q over time to give the accumulated volume (volume totalisation).

The methods are Fixed k (a user-defined velocity coefficient), Profile (a power-law profile), Log (a logarithmic profile) and Entropy (Chiu's entropy method). Each makes different assumptions about how the measured velocity relates to the mean velocity that discharge needs.

Log uses water depth and the bed roughness class to estimate depth-averaged velocity. Its theoretical basis lies in the Reynolds-averaged Navier–Stokes equations, combined with standard assumptions for turbulent open-channel flow.

Reference discharge measurements help determine suitable parameters and assess the results at your site.

Streamlines of a Burgers vortex on a black background: thin tubes spiral inward towards a tilted red axis and stretch out along it, coloured blue and turquoise to orange by angular velocity around the axis. Plays or pauses a silent 9-second loop of the same view.
Illustration, not a calculation made by the device: a Burgers vortex, an exact solution of the Navier–Stokes equations (own rendering). The flow spirals inward and stretches along the axis; colour shows angular velocity around the axis.

What each method assumes

The radar reads the water surface, and friction at the bed slows the water below it, so the surface runs faster than the section average. Profile and Log describe how the velocity changes with depth (the log law is derived below). Fixed k is a value you set, not a profile model; a reference measurement at the site can give a basis for it. Entropy relates the mean velocity to the maximum velocity of the cross-section. SVR does not solve the Navier–Stokes equations.

River reach with streamlines coloured green to red by speed: slowest near the bed and the banks, fastest just below the surface in mid-channel of this narrow channel, with eddies behind a bridge pier. A radar held above the bridge railing aims a 12° beam at the surface, where 24 Scan bins are marked. Plays a silent 11-second loop of the same view.
Streamlines from a large-eddy simulation (lattice Boltzmann method) of a straight 4 m × 2 m channel with a bridge pier: time-averaged flow upstream, instantaneous flow around the pier. Colour = speed, line width = vorticity. Radar beam, footprint and labels are schematic. Illustration with simulated values, not a field measurement. In this narrow channel (width 2 × depth) the fastest water lies just below the surface, so the maximum seen at the surface is not the maximum of the cross-section; the channel is not the worked example used in the figures below.
How the velocity profiles look

Loading the figure…

Left: two textbook velocity profiles and the k each one gives. Right: Entropy (Chiu), mean velocity from the fastest point, φ(M) · umax; schematic section.Top: two textbook velocity profiles and the k each one gives. Bottom: Entropy (Chiu), mean velocity from the fastest point, φ(M) · umax; schematic section.
From Navier–Stokes to k, step by step

The software evaluates the resulting velocity-profile relationships; it does not perform a full three-dimensional flow simulation.

  1. Navier–Stokes. ρ (∂u/∂t + (u · ∇) u) = −∇p + μ ∇²u + ρ g, with ∇ · u = 0. In a river the Reynolds number is typically 10⁵ to 10⁷, so the flow is turbulent.
  2. Time averaging (RANS). Splitting the velocity into a mean and a fluctuation adds the Reynolds stress −ρ ⟨u′w′⟩, a new unknown. It needs a closure model, which is an assumption, not a result of the equations.
  3. Closure near the bed. Prandtl's mixing length l = κ z, with κ ≈ 0.41, gives dū/dz ≈ u*/(κ z).
  4. Log law. ū(z) = (u*/κ) ln(z/z0). z0 is the roughness length; the device's bed roughness classes (Bed: Smooth, River, Rough) use 0.5, 2 and 10 mm.
  5. Depth-averaged velocity over surface velocity. k = (ln(h/z0) − 1 + z0/h) / ln(h/z0). u* and κ cancel, so k depends only on the ratio of depth to roughness, h/z0.
  • Power law (method Profile): u/us = (z/h)1/n, an empirical profile; k = n/(n + 1).
  • Entropy (method Entropy, Chiu): a maximum-entropy velocity distribution, statistical and not derived from Navier–Stokes; mean velocity = φ(M) · umax. The device shows φ(M) as k, but it relates the mean to umax, not to the surface reading.

Worked example: slope 0.001, depth 1 m, River bed (z0 = 2 mm): u* = 0.099 m/s, surface velocity 1.50 m/s, mean velocity 1.26 m/s, k = 0.839, Reynolds number about 1.3 million for water at 20 °C. Calculated, not measured.

Velocities in the river figure are scaled to a centre-line surface velocity of 1.2 m/s.

Background: whether smooth solutions of the three-dimensional Navier–Stokes equations exist for all time is one of the Clay Mathematics Institute's Millennium Prize Problems. The device's calculation does not depend on the answer.

The radar measures the surface. Software 5.0 gives you four ways to estimate the mean velocity.

With any method, Q = v · k · A. In Discharge mode Fixed k, Profile and Log read the radar value as a representative surface velocity and apply one k to the whole area A. Profile and Log describe a single vertical line (depth-averaged velocity), so taking it as the mean velocity of the whole cross-section is an assumption. Entropy reads the value as the maximum velocity of the cross-section, umax; its factor φ(M), shown as k, relates the mean to that maximum and so also allows for the slower water near the banks and the bed. At the default M 2.10 its Q is lower.

The fastest velocity the radar sees at the surface is not always the maximum of the cross-section, which can lie below the surface. Scan Section does not use this single-k approach: it builds the discharge from the slices of the cross-section (see below).

SVR-3 Pro Software 5.0 settings screen for discharge: Method Entropy, M 2.10, k 0.663.
Choosing the method on the device (simulator screen, Software 5.0.130).
Four ways to turn a reading into dischargeComparison of the four Software 5.0.130 flow methods: Fixed k (k 0.85), Profile (power law, k = n/(n+1) = 0.857 for River), Log (k = 0.839 for River, depth 1 m) and Entropy (k = phi(M) = 0.663 for M 2.10). Fixed, Profile and Log treat the reading as the representative surface velocity; Entropy treats it as the fastest point in the section (u_max). For a reading of 1.20 m/s and an area of 5.0 square metres the example discharge is 5.10, 5.14, 5.04 and 3.98 cubic metres per second. Entropy is lower because of its different assumption, not a different river. A decision tree follows: site k or M known from discharge measurements, use Fixed k or Entropy with that M; bed type known, use Profile (bed only) or Log (bed and depth); Scan surface velocity map or aiming at the fastest point, use Entropy and Scan Q; otherwise Fixed k 0.85 as a starting point. Bed means bed roughness class. Illustration with simulated values, not a field measurement.Four ways to turn a reading into dischargeExample: radar reading 1.20 m/s, cross-section area A = 5.0 m². Q = v · k · A.Fixed kk = user valuek 0.50–1.00, default 0.85 (a setting, nota measurement)k = 0.85reading = representativesurface velocitysurface velocity v1.20 m/smean = k × v1.02 m/sQ = 1.20 × 0.85 × 5.05.10 m³/sProfileu / us = (z / h)^(1/n)k = n / (n + 1)Bed: Smooth n 7 · River n 6 · Rough n 4k = 0.857reading = representativesurface velocitysurface velocity v1.20 m/smean = k × v1.03 m/sQ = 1.20 × 0.8571 × 5.05.14 m³/sLogk =ln(h / z0) − 1 + z0 / hln(h / z0)Bed: z0 0.5 / 2 / 10 mmDepth h 0.1–20 m (here River, h 1 m)k = 0.839reading = representativesurface velocitysurface velocity v1.20 m/smean = k × v1.01 m/sQ = 1.20 × 0.8394 × 5.05.04 m³/sEntropyk = φ(M) = eM / (eM − 1) − 1 / Mmean = φ(M) · umaxM 0.50–6.00, default 2.10k = 0.663reading = fastest pointin the section (umax)umax1.20 m/smean = φ(M) × umax0.80 m/sQ = 1.20 × 0.6634 × 5.03.98 m³/sEntropy reads the radar value as the fastest velocity in the section (umax), so its Q is lower in this example:a different assumption, not a different river.Which method?Site k or M known fromdischarge measurements?yesFixed k / Entropy with that MnoBed type known (depth too)?yesProfile (bed only) / Log(bed + depth)noSurface velocity map with Scan,or aiming at the fastest point?yesEntropy (+ Scan Q)noFixed k 0.85 as a starting pointBed = bed roughness class (not the cross-section shape)Illustration with simulated values, not a field measurement. Four ways to turn a reading into dischargeComparison of the four Software 5.0.130 flow methods: Fixed k (k 0.85), Profile (power law, k = n/(n+1) = 0.857 for River), Log (k = 0.839 for River, depth 1 m) and Entropy (k = phi(M) = 0.663 for M 2.10). Fixed, Profile and Log treat the reading as the representative surface velocity; Entropy treats it as the fastest point in the section (u_max). For a reading of 1.20 m/s and an area of 5.0 square metres the example discharge is 5.10, 5.14, 5.04 and 3.98 cubic metres per second. Entropy is lower because of its different assumption, not a different river. A decision tree follows: site k or M known from discharge measurements, use Fixed k or Entropy with that M; bed type known, use Profile (bed only) or Log (bed and depth); Scan surface velocity map or aiming at the fastest point, use Entropy and Scan Q; otherwise Fixed k 0.85 as a starting point. Bed means bed roughness class. Illustration with simulated values, not a field measurement.Four ways to turn a readinginto dischargeExample: radar reading 1.20 m/s, cross-section area A= 5.0 m². Q = v · k · A.Fixed kk = user valuek 0.50–1.00,default 0.85(a setting, not ameasurement)Q = 5.10 m³/s1.20 × 0.85 × 5.0of v = 1.20 m/smean 1.02 m/sreading =representativesurface velocityk =0.85Profileu / us = (z/h)^(1/n)k = n / (n + 1)Bed: Smooth n 7,River n 6, Rough n 4Q = 5.14 m³/s1.20 × 0.8571 × 5.0of v = 1.20 m/smean 1.03 m/sreading =representativesurface velocityk =0.857LogL = ln(h / z0)k = (L − 1 + z0/h) / LBed: z0 0.5 / 2 / 10 mmDepth h 0.1–20 m(here River, h 1 m)Q = 5.04 m³/s1.20 × 0.8394 × 5.0of v = 1.20 m/smean 1.01 m/sreading =representativesurface velocityk =0.839Entropyk = φ(M) =eM/(eM−1) − 1/MM 0.50–6.00,default 2.10Q = 3.98 m³/s1.20 × 0.6634 × 5.0of umax 1.20 m/smean 0.80 m/sreading =fastest pointin the section(umax)k =0.663Entropy reads the radar value as the fastestvelocity in the section (umax), so its Q is lower inthis example: a different assumption, not adifferent river.Which method?Site k or M known from discharge measurements?yesFixed k / Entropy with that MnoBed type known (depth too)?yesProfile (bed only) / Log (bed + depth)noSurface velocity map with Scan, or aiming at thefastest point?yesnoEntropy (+ Scan Q)Fixed k 0.85 as astarting pointBed = bed roughness class (not the cross-sectionshape)Illustration with simulated values,not a field measurement.
Same reading, four assumptions. Input for every card: surface velocity 1.20 m/s, area 5.0 m². k is shown as the device logs it, to three decimals; Q is computed with the full value.

Exactly 10 m/s over 5 m² (a deliberately round number, not a river velocity) gives 42.50 m³/s with Fixed k 0.85 and 33.17 m³/s with Entropy at the default M 2.10, about 22 % less. A lower Q is not better or worse in itself: the difference comes from what each method takes the reading to be, a representative surface velocity or umax. Reference discharge measurements show which assumption suits your site.

  1. Site k or M known from discharge measurements? → Fixed k, or Entropy with that M
  2. Bed type known (depth too)? → Profile (bed only) or Log (bed and depth)
  3. Surface velocity map with Scan, or aiming at the fastest point? → Entropy (and Scan Q)
  4. None of these? → Fixed k 0.85 as a starting point

Bed = bed roughness class, not the shape of the cross-section. Bed is greyed out with Fixed k and Entropy. The shape of the cross-section is set separately, in Scan setup → Section.

With a surface velocity map from Scan and an estimate of the river's width and depth, Scan Section (below) calculates Q from the map.

Without a section, Scan works with the Entropy method. On a tripod, you tilt the device down in steps and it assigns each accepted reading to its distance bin (24 bins); the radar delivers about 7 readings per second, and readings count while the device is held still. With the shape Off and Method Entropy, the fastest bin becomes umax, and Scan Q = φ(M) · umax · A, with the area A you entered, is written to the session summary in the log file with Datalog on (use a speed unit in Scan). The fastest bin is the maximum on the water surface; whether it stands in for the maximum of the whole cross-section is a judgement you make at the site. With a section set, the area is computed and the discharge is built from the slices of the cross-section instead, and Q and Cov appear on the device: see below.

Scan + Entropy → Scan QScan map of 24 distance bins across a river, seen from above with the device on the bank at radar height 5 m, horizontal angle 35 degrees. Bins are coloured green to red with the device speed scale. The fastest bin, over the centre line with 1.20 m/s, is marked as u_max. Scan Q = phi(M) times u_max times A = 0.6634 x 1.20 m/s x 5.0 m2 = 3.980 m3/s. The radar delivers about 7 readings per second; readings count while the device is held still. Bins are idealised; at shallow angles the beam footprint spans many bins. Illustration with simulated values, not a field measurement.Scan + Entropy → Scan QTilting the device in Scan mode fills 24 distance bins. The fastest bin is taken as umax; with area A and M, Entropy gives Q.1 Scan: 24 distance bins across the riverPlan view. Device on the bank, radar height hr = 5 m, H = 35°, Auto 25°near bankfar bankcentre lineflowH 35°fastest binumax = 1.20 m/sSVR on tripodx = 2.89 m10.72 mx = hr / tan V2 Pick the fastest binBin colours use the device scale (Auto): green = low, red = high.umax = 1.20 m/s3.05 m10.56 mx of bin centres1.101.20bin mean speed, m/sumax = mean of the fastest filled bin.3 Scan QQ = φ(M) · umax · A= 0.6634 × 1.20 m/s × 5.0 m²= 3.980 m³/sScan Q: 3.980 m3/s (u_max 1.20 m/s, A 5.0 m2)device log line; M = 2.10 gives φ(M) = 0.6634The radar delivers about 7 readings per second; readings count while the device is held still.Bins idealised; at shallow angles the beam footprint spans many bins.At H 35° the bins nearer than x = 6.3 m (V above 38.3°) also raise the device's combined-angle indicator; the measurement continues.Illustration with simulated values, not a field measurement. Scan + Entropy → Scan QScan map of 24 distance bins across a river, seen from above with the device on the bank at radar height 5 m, horizontal angle 35 degrees. Bins are coloured green to red with the device speed scale. The fastest bin, over the centre line with 1.20 m/s, is marked as u_max. Scan Q = phi(M) times u_max times A = 0.6634 x 1.20 m/s x 5.0 m2 = 3.980 m3/s. The radar delivers about 7 readings per second; readings count while the device is held still. Bins are idealised; at shallow angles the beam footprint spans many bins. Illustration with simulated values, not a field measurement.Scan + Entropy → Scan QTilting the device in Scan mode fills 24distance bins; the fastest is taken as umax.1 Scan: 24 bins across the riverPlan view. hr = 5 m, H = 35°, Auto 25°near bankfar bankcentre lineflowH 35°fastest binumax = 1.20 m/sSVR on tripodx = 2.89 m10.72 mx = hr / tan V2 Pick the fastest binBin colours use the device scale (Auto): green = low,red = high.umax = 1.20 m/s3.05 m10.56 mx of bin centres1.101.20bin mean speed, m/sumax = mean of the fastest filled bin.3 Scan QQ = φ(M) · umax · A= 0.6634 × 1.20 m/s × 5.0 m²= 3.980 m³/sScan Q: 3.980 m3/s(u_max 1.20 m/s, A 5.0 m2)device log line; M = 2.10 gives φ(M) = 0.6634The radar delivers about 7 readings per second;readings count while the device is held still.Bins idealised; at shallow angles the beam footprintspans many bins.At H 35° the bins nearer than x = 6.3 m (V above38.3°) also raise the device's combined-angleindicator; the measurement continues.Illustration with simulated values,not a field measurement.
Scan + Entropy: discharge from a surface velocity map. Simulated channel, radar 5 m above the water, H 35°, Auto 25°. Bins idealised; at shallow angles the beam footprint spans many bins. umax is taken at the surface here; in a narrow channel it can lie just below it (river figure).
More on the Scan map

At this example's H 35°, the steepest bins (V above 38.3°) also raise the device's combined-angle warning.

Discharge estimation with Scan Section (Software 5.0.130)

Scan Section combines the surface velocities measured by Scan with the cross-section you describe. For each slice (subsection) of the cross-section the software applies a logarithmic velocity-profile model to estimate the depth-averaged velocity, and the slices are added together to give the discharge. The area is computed from your description, not entered. Scan Section always applies the log-law profile with the Bed class, whichever Method is selected in Flow/Discharge. The result depends on the geometry you enter, the bed roughness class, the measurement coverage (Cov) and how well the flow assumptions fit the site.

Oblique view of a river reach with a bridge and the SVR-3 Pro in an inset. A 12° beam crosses the river; 15 bins on the surface are coloured green to red by surface velocity, and a translucent cross-section of slice columns rises from the bed. Readout: Q 5.74 m³/s, Cov 70 %. Plays or pauses a silent 12-second loop of the same view.
Scan Section in one view: the bins across the river (15 of the 24 are on the water) and the cross-section built from them. Column height is depth and colour is surface velocity; hatched columns have no bin. Depth is exaggerated 2.5 times so the shape is easy to see. The animation shows the device tilting step by step, the bins lighting up across the river and the cross-section rising from the bed as slices coloured by surface velocity; Q and Cov appear at the end. Simulated example: radar on a bridge above the bank, 3 m back from the water's edge (Radar −3.0 m) and 10 m above the water; W 8.0 m, Parabola, D 1.00 m, H 25°. Illustration with simulated values, not a field measurement.

In SET → Next → Scan setup → Section you set W (water width, edge to edge), Radar (where the radar stands across the river, measured from the water's edge you start from: negative behind that edge, on the bank; positive out over the water, as on a bridge), D (largest depth; an estimate is enough), the shape (Rectangle, Trapezoid with banks 1:2, or Parabola) and the beam direction (To far or To near). The bed roughness class (Bed) comes from Flow/Discharge.

After STOP the device builds the depth profile from D and the shape and sums the slices: surface velocity × log-law k for that depth × slice area. Shallow slices get a smaller k, and the velocity is assumed to fall towards the banks. Page 2 of the summary shows Q in m³/s and Cov, the share of the section under measured bins. Q is always an estimate built from your description of the river; under 50 % both turn red, because most of the section was not measured.

SVR-3 Pro Section screen: rows W 8.0m, Radar -3.0m and D 1.00m, each with + and − buttons; shape button Parabola; direction button To far; Back, Main and OK below.
Describing the river on the device: SET → Next → Scan setup → Section (simulator screen, Software 5.0.130).
SVR-3 Pro session summary page 2 of 3 after a Scan: Min 0.7 m/s, Max 2.2 m/s, Avg 1.5 m/s, N 118, Q 5.74 m3/s and Cov 70 %, with the values in yellow.
After STOP, page 2 of the summary shows Q and Cov (simulator screen, Software 5.0.130). Illustration with simulated values, not a field measurement.
SVR-3 Pro session summary page 2 of 3 after a Scan: Min 0.7 m/s, Max 2.2 m/s, Avg 1.5 m/s, N 118, then Q 4.39 m3/s and Cov 43 % in red.
The same readings with Radar −5.0 m instead of −3.0 m: two bins fall on the bank, Cov drops to 43 % and Q and Cov turn red: most of the section was not measured (simulator screen, Software 5.0.130). Illustration with simulated values, not a field measurement.
How to describe the river: radar position, width, depth and shape

Loading the figure…

Describe the river: from the bank (left) or a bridge (right), Radar is where the radar stands across the river, measured from the water's edge you start from. W is the water width and D the largest depth. Shapes: Rectangle, Trapezoid (banks 1:2), Parabola (deepest in the middle). The bed roughness class (Bed) comes from Flow/Discharge.
How the surface velocity map becomes a discharge, step by step

Loading the figure…

From the map to a discharge: each measured bin has a place across the river; the section is cut into slices; each slice gets its surface velocity, a log-law k for its depth and its area; Q is the sum and Cov the share of the section under measured bins. Simulated example, W 8.0 m, Parabola, D 1.00 m, H 25°.
More on Scan Section

Coverage. Cov is the share of the cross-section area A that lies under measured bins on the water (their spans across the river), as a percentage of A. Between measured bins the software interpolates the velocity, and between the outermost measured bin and the water's edge it assumes the velocity falls towards the bank. These parts are included in Q but not in Cov. Bins that land on the bank are excluded from the calculation. At shallow angles the beam footprint can cover several distance bins, so neighbouring bins are not independent point measurements.

Inputs and assumptions. W, D and the shape are estimates. Depth affects both the area and the k of each slice, so its effect on Q depends on the shape: in a worked calculation for Software 5.0.130, 10 % more D gave about 10 % more Q for Rectangle and Parabola sections, and less for a wide Trapezoid, because the bank width changes with D. Treat this as an example, not a rule. The reach is taken as uniform (the bins lie at different points along the flow) and the flow as parallel to the banks. H is set, not measured; its error shifts every bin across the river and changes the angle correction applied to every reading. Scan Section needs the beam to point across the river (the examples use H 25°); the larger H, the larger the angle correction, so set H carefully and keep ANGLE WARN off. From the bank, part of the window can land on dry ground or stop short of the far bank, so Cov drops; from a bridge, more of it can lie over the water.

Display and log. Q and Cov are shown on page 2 of the summary. The k on page 1 belongs to the Method selected in Flow/Discharge; Scan Section's Q does not use it but its own log-law k for each slice. No Q appears with the shape Off (Scan then works as before), with H at or near 0° (the beam has to point across the river), with a flow unit selected (use a speed unit in Scan), or when no measured bin lies on the water. With Datalog on, the log keeps the section settings, Q, area, mean velocity and Cov, so the inputs behind each Q stay on record.

Treat the result as an estimate built from your description of the river until you have compared it with a discharge measured at the site.

None of this replaces measuring your site: a discharge measured there, with an ADCP or by wading, is the best basis, whether it gives you a k or M or a check on Scan Section.

Fitting k or M, and what is logged

Enter a k found this way as Fixed k, or an M in Entropy; k is determined from reference measurements, not measured directly. φ or M should be fitted with the same aiming or Scan practice as the measurement. Until you have one, the methods give a reasoned starting point. With Datalog on, every session logs the method, its parameters and the k used, so Q can be recomputed later. With a section set, the section settings, the computed area and the coverage are logged as well.

Sources: Clay Mathematics Institute, Navier–Stokes Equation (Millennium Prize Problems); J. W. Fulton, F. L. Engel, J. R. Eggleston and C.-L. Chiu, Computing discharge using the entropy-based probability concept, USGS Techniques and Methods 3-A26, 2025.

A wave is not a flow reversal

With the direction set to Both, the device watches the prevailing direction. Once at least 8 readings are in and 80 % go one way, a reading the other way is left out. If the opposite readings continue, the third in a row counts as a real change of direction and from then on they are used.

Each stem is one radar reading, up towards the radar and down away from it. Use Towards or Away in SET to accept only one direction. The data log records how many readings were left out.

Automatic radar check at power-on

At power-on the device configures the radar and reads every setting back. Green OK on each line means the radar is ready. Restored counts the settings it had to rewrite, which is normal after a radar replacement or a service connection, as in this example.

Radar configuration check: all lines OK, transmitter OFF, restored 21

Every measurement session includes a status

COMPLETE
Measurement completed under the mode's acceptance criteria. Average: all samples in. Discharge: the whole duration covered without gaps. The status describes the measurement session, not whether A, k or the cross-section are correct.
INCOMPLETE
A result exists but is partial: stopped early, too few samples or gaps.
NO DATA
No readings. Check the aim, the surface and the sensitivity.
ANGLE WARN
The combined angle between beam and flow, θ = arccos(cos V × cos H), passed 50°: reduced accuracy.
INVALID
The angle left its limits during the session. Repeat the measurement.

Your data, with its context

With Datalog on, every session goes to the SD card with time, GPS position (when the receiver has a fix), serial number, firmware version, settings, angles, angle correction factor, result and status. No phone or app is needed in the field.

SVR-3 Pro software 5.0 GPS Position in each record, when it has a fix Clock set from satellite time microSD data log Datalog.txt, up to 16 MB, managed USB Download the log to a computer RS-485 Each surface velocity reading, live, to an external logger
The log mark on the main screen turns red at 90 % of 16 MB and shows FUL when full, so logging never stops unnoticed.
Each SCAN line records
GeometryTime from START (ms), vertical angle, roll, horizontal distance x from the point directly below the radar, sideways distance x · sin H, distance step
SpeedSpeed, the radar's own reading, the peak speed in the footprint
QualitySignal strength, directionality, tilt rate in degrees per second, how the reading was accepted

With a river section set, the session summary in the log also records the section (width, radar position, largest depth, shape, beam direction and bed class), Q, the computed area, the mean velocity and the coverage.

Who measures with it

Anyone who needs to measure surface velocity or estimate discharge where wading is unsafe, slow or impossible. You measure from a bridge, a river or canal bank or another elevated spot with a clear view of the water.

Hydrological services
High-flow gaugings for the top of the rating curve, and quick check measurements between station visits.
Flood monitoring and emergency response
A fast surface velocity reading from a bridge or the bank during a flood, without anyone entering the water.
Engineering consultants
Hydrological surveys, environmental assessments and flood-risk mapping across many sites.
Universities
Field courses and research, with raw Scan data that opens in a spreadsheet.
Water and wastewater utilities
Flow checks at stormwater and sewer outfalls, overflows and treatment plant channels.
Hydropower and irrigation
Check measurements in canals, bypass channels and fish passes.
Mines and industry
Discharge ditches and outlet flows under permit monitoring.

Specifications

SVR-3 Pro 2026 rendered from the front left: ribbed antenna housing with lens, display window and grip with battery.
Loads a 2.7 MB 3D model.
SVR-3 Pro, 2026. 3D model: a rendering, not a photograph. Drag to rotate; on iPhone, iPad and supported Android phones, view it in your own space.
Close-up of the USB-B port in its threaded collar with a red O-ring
USB port, IP67 rated: the screw cap seals against the red O-ring.
RadarKa-band Doppler radar module, 12° beam
Angle sensorBuilt-in; about ±1° after Zero V and Cal tilt. A 1° angle error changes the surface velocity result by about 1 % at a 30° tilt and about 3 % at 60° (H = 0).
Resolution0.1 km/h (0.028 m/s)
Unitskm/h, mph, m/s, ft/s, cm/s; discharge in m³/s or ft³/s
ModesNormal; Upper median of 4; Average of 2–20 samples; Discharge over 10–300 s; Scan
Tilt range0–60° below horizontal; Scan map 25–60° (Auto window 15°/20°/25° or manual down to 10°)
Horizontal angle0–45°, set by the operator
ScanRadar height 0.5–30.0 m, 24 distance bins, about 7 readings per second, HOLD acceptance; optional river section for discharge from the map (metres; Q in m³/s): width 0.1–500 m, radar position from the water's edge (bank or bridge), largest depth 0.05–20 m, Rectangle / Trapezoid / Parabola, beam To far / To near
DischargeArea 0.1–99.9 m² (ft² with ft³/s); velocity coefficient k as a fixed value 0.50–1.00 or from the Profile, Log or Entropy method (k limited to 0.30–1.00); totaliser ABS / POS / NEG / NET. In Scan with a section set: area computed from the section, k from the log law at each depth, Q and coverage on the summary
Direction filterBoth, Towards or Away; lone opposite readings left out with Both
Display2.4-inch colour touch screen, 320 × 240
DataSD card; log file Datalog.txt up to 16 MB; USB download; RS-485 serial mirroring; GPS position and clock
ProtectionIP67
USB portUSB-B; the tethered screw cap seals against a red O-ring
OptionsAnalogue output module for fixed sites: 4–20 mA, 0–10 V or ±10 V from the serial flow data, with two programmable alarm relays
PowerMakita 18 V Li-ion tool battery: BL1820 (2.0 Ah) supplied; BL1815 also fits. USB alone runs the display, not the radar.
Battery lifeA full working day with a 5.0 Ah battery: about 10 h of continuous use; about 4 h of continuous use with the supplied 2.0 Ah battery (BL1820). Calculated with the transmitter on continuously.
How this is calculated

Calculated, not measured: pack energy 2.0 Ah × 18 V = 36 Wh (5.0 Ah: 90 Wh), 90 % of it usable, 20 °C. The radar module is assumed to draw 370 mA (specified at 12 V), drawn at 18 V the whole time, with the transmitter on continuously. The rest of the device (display with backlight at full brightness, GPS, SD card, processor) is estimated at about 1.2 W. Cold weather and an old battery shorten the time. The transmitter is on only while a measurement is running; between measurements the radar draws about a quarter of that current, so typical field use lasts longer. The 1.5 Ah BL1815 is not covered by this figure.

Software5.0 (firmware 5.0.130, October 2026)

SVR-1 Pro and SVR-3 Pro

Two housings, one instrument. SVR-1 Pro has the same measurement functions, screen and data handling as SVR-3 Pro. It is built for fixed sites and runs on an external battery or a fixed power supply.

SVR-3 Pro from the rear: ribbed aluminium body, sealed USB port and teal grip
SVR-3 ProHandheld, or on a tripod
SVR-1 Pro seen from below: radar dome, ribbed aluminium housing, cable connector and tripod mount
SVR-1 ProFixed sites, or on a tripod
SVR-3 ProSVR-1 Pro
UseHandheld measurements, or on a tripodFixed sites at bridges and channels, or on a tripod
Measurement modesSame in both: Normal, Median, Average, Discharge and Scan
Radar and anglesSame in both: Ka-band Doppler radar, 12° beam, built-in angle sensor with V and H correction
ScreenSame in both: 2.4-inch colour touch screen
DataSame in both: SD log with time and GPS position, USB download, RS-485 serial mirroring
PowerMakita 18 V Li-ion tool battery in the gripExternal battery or fixed power supply
SVR-1 Pro on a tripod at a footbridge over a canal, its screen facing the operator
SVR-1 Pro on a tripod at a footbridge, screen towards the operator.

Questions

Do I need a phone or an app?

No. Everything runs on the device: the colour touch screen, the settings, the session summary and the data log. A computer is only needed to download the log.

Where can I measure from?

From a bridge, a river or canal bank, a weir or culvert walkway, or any other elevated spot with a clear view of the water surface. Choose a stable position away from the water's edge. The device corrects the reading for the tilt angle. For Scan you enter the radar height above the water, 0.5–30 m.

What kind of water surface does it need?

A steady, rippled surface. A mirror-smooth surface gives weak or no radar returns. Raise the sensitivity (1–4) for smooth water and lower it if spray, rain or nearby movement is picked up.

How does surface velocity become discharge?

The radar measures surface velocity v. The software estimates the mean velocity from it, using the site information and the method you chose for the velocity coefficient k, and calculates discharge as Q = v × k × A, with A the cross-sectional area. In Discharge mode the volume of the measurement period is Q integrated over time (volume totalisation). The result depends on A and on how well k suits the site. In Scan with a river section set (Scan setup → Section), the device calculates the discharge slice by slice from the Scan surface velocities and your estimate of width, depth and shape, applying the log-law profile, computes the area itself and shows Cov, the share of the section under measured bins. There the depth estimate D also matters: in the Rectangle and Parabola examples a 10 % error in D gives about 10 % in Q, in a wide Trapezoid less.

How accurate is a reading?

The reading resolves 0.1 km/h (0.028 m/s). Resolution is the smallest step the display shows; it is not the accuracy of the measurement, and neither is the same as measurement uncertainty, which also depends on the site, the aim and the surface. One contribution you can control is the angle: a 1° error in V changes the surface velocity result by about 1 % at a 30° tilt and about 3 % at 60° (H = 0), so keep V at 30–45° and H small. A discharge result also depends on A and k being right for the site and, with Scan Section, on the depth estimate D (see the previous question).

How do I know a measurement is good?

Every session ends with a status: COMPLETE, INCOMPLETE, NO DATA, ANGLE WARN or INVALID, together with the angle correction factor and the number of readings left out. The status describes the measurement session, not whether the inputs A, k and the cross-section are right; those are yours to check. With Datalog on, the same is written to the data log. Each software release is verified against a documented measurement specification with our own automated test suite.

How do I get the data out?

Press LOG, then Send data to USB, and receive Datalog.txt in a serial terminal at 9600 baud or in the service tool. For live data, turn on Serial Mirroring and connect a logger to RS-485.

What powers it?

A Makita 18 V Li-ion tool battery on a slide-on adapter. USB power runs the display only; the radar and the angle readings need main power.

How long does the battery last?

A full working day with a 5.0 Ah battery: about 10 h of continuous use; about 4 h of continuous use with the supplied 2.0 Ah battery (BL1820). Calculated with the transmitter on continuously. The assumptions are under Battery life in the specifications.

Someone had to go first.

Since 2012, one evolving family of instruments: from an add-on logger to a software rewrite in 2026. Every date below comes from our own offers, brochures, release records and invoices.

    Scroll to move through the years.

    Who did it first

    The year each capability first appears in public material for a handheld surface velocity radar, by manufacturer. Dates come from archived web pages, brochures, manuals and offers.

    Each mark is the earliest dated evidence we found, so a feature may be older than shown. First on this page means first to our knowledge, based on the sources below. Handheld units only, with the calculation done in the unit; PC software and fixed or rail-mounted systems are not counted.
      Sources and method

        Software 5.0, a rewrite of the instrument firmware

        The SVR-3 Pro hardware platform has carried three software generations since 2017. Version 5.0 keeps the familiar workflow of 4.2 and adds discharge, Scan, measurement statuses and releases verified with our own automated test suite.

        Version 3.4 (2017)Version 4.2 (2025)Software 5.0 (2026)
        ModesContinuous readingNormal, MedianNormal, Median, Average, Discharge, Scan
        Discharge––Discharge Q = v × k × A, volume totalised over time, coverage and gap report
        Scan––Surface velocity map from tilting the radar, distance window, waterfall view, raw SCAN log; discharge from the map and an estimated cross-section, with coverage
        AnglesTilt sensor, manually entered horizontal angle HV and H correctionTwo-axis tilt with roll, zero protection, guided Cal tilt, 50° warning
        Session resultReading on screenReading on screenStatus, three summary pages, angle correction factor, rejection counts
        RadarFixed set-upConfigured at startConfiguration read back at every start, automatic restore
        Data logSurface velocity, date and timeSD log with GPSFull session records, 16 MB management, Scan raw data, USB download
        ClockManualManualManual or GPS synchronised, with time zone
        Verification––Each release verified against a documented measurement specification with our own automated test suite

        Used by

        • National Observatory of AthensNational Observatory of Athens
        • Proyecto Especial Regional Pasto Grande, PeruProyecto Especial Regional Pasto Grande, Peru
        • SENAMHI, Peru's national meteorological and hydrological serviceSENAMHI, Peru's national meteorological and hydrological service

        Since 2004.The flow must go on.

        Ask for a quote or a field demonstration

        Tell us the site, the typical flow range and how you measure today. We reply with a quote and, where possible, a demonstration at your site.

        Viatronics Oy Pitkänsillankatu 8 67100 Kokkola, Finland

        +358 207 528 570
        viatronics.eu/contact